VX120+

Unique diagnostic device for the anterior chamber, screening and analysis of the vision. Make the difference thanks to the VX120+, complete and fully automatic diagnostic screening device. Complete refraction, differentiate between day and night vision needs, glaucoma, cataract, keratoconus identification and monitoring , fitting of contact lenses.

  • Complete Refraction Differentiate Between Day And Night Vision needs

  • Glaucoma Identification and monitoring

  • Keratoconus Identification and monitoring

  • Identification of a cataract

  • VX120+ Ready for communication

Complete Refraction
Differentiate Between Day And Night Vision needs

  • Objective day and night refraction measurements
  • 1300 points points analyzed for a 7-mm diameter pupil
  • Objective refraction under mesopic and photopic conditions
  • Measures lower-order and higher-order aberrations
  • Access visual acuity and quality of vision on a pupil as small as 1.2 mm
  • MTF curve

Technology
Shack-Hartmann wavefront analysis

Glaucoma
Identification and monitoring

  • Anterior chamber analysis
  • Automatic measurement of iridocorneal angles
  • Measurement of anterior chamber volume
  • Measurement of anterior chamber depth
  • Measurement of IOP (intraocular pressure)
  • Measurement of corneal thickness
  • Corrected IOP as a function of corneal thickness

Technology
Scheimpflug imaging and non contact tonometer with soft air puff.  

Keratoconus
Identification and monitoring

Topography maps

  • Axial, tangential elevation and refraction maps
  • Keratoconus probability index (KPI)
  • Keratoconus monitoring
  • Internal astigmatism measurement
  • Eccentricity and meridian tables
  • Corneal aberrometry

Technology
Wavefront analysis with Shack-Hartmann technology , Placido rings, Scheimpflug imaging

Identification of a cataract

  • Visualization of crystalline opacities
  • Analysis of wavefront aberrations, with the ability to separate corneal and lenticular/internal aberrations
  • Internal astigmatism measurement
  • Kappa angle for IOL centering
  • Z.4.0 value for aspheric implant
  • Lens opacity classification (LOCS II and III scales)

Technology
Scheimpflug imaging , Retroillumination, Shack-Hartmann, Placido rings

VX120+ Ready for communication

The VX 120 + can be set up in a network to integrate with your patient management software and provide a variety of communication options to optimize your work flow.

  • Review results from any supported device (tablet, smartphone, etc.)
  • Print directly from your local or network printer
  • Customize your reports
  • Synchronize data, graphs, and maps for any examination
  • Communication enabled with other instruments