OPHTEIS Adaptive Pro
Visco cohesive containing sorbitol to adapt&protect
Ophteis Adaptive PRO is designed for surgeons who require versatility and
protection throughout the procedure.
Based on advanced rheological technology, Ophteis Adaptive PRO
combines chamber stability with sustained endothelial cell protection,
reducing the need to switch between multiple OVDs for most cases.
Ophteis Adaptive PRO’s high viscosity supports reliable anterior chamber
maintenance during the capsulorhexis and phacoemulsification, while
maintaining predictable handling characteristics during IOL implantation.
The visco-adaptive nature of the OVD flows smoothly during injection,
remains stable when needed and can be removed in a controlled manner
at the end of surgery.
In addition to its reliable mechanical performance, Ophteis Adaptive PRO
contains 4% sorbitol, a free-radical scavenger designed to help neutralise
reactive oxygen species generated during phacoemulsification.
By addressing oxidative stress as well as mechanical trauma, it offers
an added dimension of intraoperative endothelial protection.
-
Designed to deliver a new level of corneal endothelial protection
-
The ONLY OVD with sorbitol free radical scavenging
-
Proven to reduce cell death by an average of 28.4% when compared to market leading OVD's
-
Unique bio-engineered composition of NaHA and sorbitol transforms the 2% NaHA dispersive solution into a viscous cohesive.
-
A larger 1.2 ml syringe gives you the confidence that Ophteis® FR Pro will support all elements of your cataract procedure
-
With its stable rheology at room temperature you will enjoy consistent performance for every procedure
-
Ophteis® FR Pro is designed to protect the endothelium, provide excellent chamber maintenance and is fully validated with all Rayner IOLs
Details
- ClassificationVisco-adaptive
- Polymer OriginBiofermentation
- NaHa concentration2.0%
- Sorbitol concentration4.0%
- Molecular weightApprox. 2.9 Million Dalton
- Zero shear viscosityAvg. 350.000 mPAS
- Shelf life2 years
- Syringe volume1.1ml
- Cannula Gauge27G
Introducing Ophteis FR Pro
We’ve put a lot of fresh thinking into our new Ophteis FR Pro. It’s a unique bio-engineered Visco-Surgical Device (OVD) containing free radical scavenging sorbitol – designed to deliver a new level of corneal endothelial protection from phaco induced trauma.
Containing sorbitol for unparalleled free radical scavenging
Sorbitol acts as an outstanding free radical scavenger, neutralising reactive oxygen species during surgery that causes damage to the endothelium. In fact, when compared to market leading OVDs, studies show that the use of Rayner’s Ophteis FR Pro reduces cell death by an average of 28.4%*.